  Description:

Clinical investigation of medical devices for human subjects - Good clinical practice (ISO 14155:2020)

  Purpose

This document addresses good clinical practice for the design, conduct, recording and reporting of clinical investigations carried out in human subjects to assess the clinical performance or effectiveness and safety of medical devices. For post-market clinical investigations, the principles set forth in this document are intended to be followed as far as relevant, considering the nature of the clinical investigation (see Annex I). This document specifies general requirements intended to — protect the rights, safety and well-being of human subjects, — ensure the scientific conduct of the clinical investigation and the credibility of the clinical investigation results, — define the responsibilities of the sponsor and principal investigator, and — assist sponsors, investigators, ethics committees, regulatory authorities and other bodies involved in the conformity assessment of medical devices. NOTE 1 Users of this document need to consider whether other standards and/or national requirements also apply to the investigational device(s) under consideration or the clinical investigation. If differences in requirements exist, the most stringent apply. NOTE 2 For Software as a Medical Device (SaMD) demonstration of the analytical validity (the SaMD’s output is accurate for a given input), and where appropriate, the scientific validity (the SaMD’s output is associated to the intended clinical condition/physiological state), and clinical performance (the SaMD’s output yields a clinically meaningful association to the target use) of the SaMD, the requirements of this document apply as far as relevant (see Reference [4]). Justifications for exemptions from this document can consider the uniqueness of indirect contact between subjects and the SaMD. This document does not apply to in vitro diagnostic medical devices. However, there can be situations, dependent on the device and national or regional requirements, where users of this document might consider whether specific sections and/or requirements of this document could be applicable.

  Publication

Wednesday 14th of April 2021

  Related Standards

EN 556-1:2001

Active implantable medical devices Directive (90/385/EEC)

Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminal...

EN ISO 11137-1:2015

Active implantable medical devices Directive (90/385/EEC)

Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a ster...

EN ISO 13485:2016

Active implantable medical devices Directive (90/385/EEC)

Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)

EN ISO 13408-7:2015

Active implantable medical devices Directive (90/385/EEC)

Aseptic processing of health care products - Part 7: Alternative processes for medical devices and combination products (ISO 13408...

EN ISO 13408-6:2011

Active implantable medical devices Directive (90/385/EEC)

Aseptic processing of health care products - Part 6: Isolator systems (ISO 13408-6:2005)

EN ISO 13408-5:2011

Active implantable medical devices Directive (90/385/EEC)

Aseptic processing of health care products - Part 5: Sterilization in place (ISO 13408-5:2006)

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0