EN IEC 60079-15:2019 Standard

wave
Save  

  Keywords:

#iec #part #edition #requirement #requirements

  Directive

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

  Last Official Journal reference

Tuesday 10th of November 2026

  Description:

Explosive atmospheres - Part 15: Equipment protection by type of protection "n"

  Purpose

IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended for use in explosive gas atmospheres. This part of IEC 60079 applies to electrical equipment where the rated input voltage does not exceed 15 kV r.m.s. AC or DC including where the internal working voltages of the Ex product exceeds 15 kV, for example starters for HID luminaires. This part of IEC 60079 supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1 (Clause 1). Where a requirement of this part of IEC 60079 conflicts with a requirement of IEC 60079-0, the requirement of this part of IEC 60079 takes precedence. This fifth edition cancels and replaces the fourth edition, published in 2010, and constitutes a technical revision. Refer to the Forward of the document for a complete listing of the technical changes between edition 5.0 and the previous edition of the document.

  Publication

Tuesday 10th of November 2026

  Related Standards

EN 14373:2021+A1:2025

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Explosion suppression systems

EN 556-1:2001

In vitro diagnostic medical devices Directive (98/79/EC)

Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminal...

EN 556-1:2001/AC:2006

In vitro diagnostic medical devices Directive (98/79/EC)

Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminal...

EN 556-2:2015

In vitro diagnostic medical devices Directive (98/79/EC)

Sterilization of medical devices - Requirements for medical devices to be designated ''STERILE" - Part 2: Requirements for aseptic...

EN ISO 11137-1:2015

In vitro diagnostic medical devices Directive (98/79/EC)

Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a ster...

EN ISO 11137-2:2015

In vitro diagnostic medical devices Directive (98/79/EC)

Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2:2013)

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0