  Description:

Flame arresters - Performance requirements, test methods and limits for use (ISO 16852:2016)

  Purpose

ISO 16852:2016 specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This International Standard is valid for pressures ranging from 80 kPa to 160 kPa and temperatures ranging from −20 °C to + 150 °C. NOTE 1 For flame arresters with operational conditions inside the scope, but outside atmospheric conditions, see 7.4. NOTE 2 In designing and testing flame arresters for operation under conditions other than those specified above, this International Standard can be used as a guide. However, additional testing related specifically to the intended conditions of use is advisable. This is particularly important when high temperatures and pressures are applied. The test mixtures might need to be modified in these cases. NOTE 3 An additional standard IMO MSC/Circ. 677 for maritime application from IMO (International Maritime Organization) exists. ISO 16852:2016 is not applicable to the following: - external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; NOTE 4 Integrated measurement and control equipment, such as integrated temperature and flame sensors as well as parts which, for example, intentionally melt (retaining pin), burn away (weather hoods) or bend (bimetallic strips), is within the scope of this International Standard. - flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (e.g. acetylene) or which are chemically unstable; - flame arresters used for carbon disulphide, due to its special properties; - flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (e.g. higher oxygen-nitrogen ratio, chlorine as oxidant, etc.); - flame arrester test procedures for internal-combustion compression ignition engines; - fast acting valves, extinguishing systems and other explosion isolating systems.

  Publication

Friday 9th of June 2017

  Reference

This standard supersedes the "EN ISO 16852:2010"

Anyway is still possible use the "EN ISO 16852:2010" until November 30th, 2017

  Related Standards

EN 16009:2011

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Flameless explosion venting devices

EN 50104:2019

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Electrical equipment for the detection and measurement of oxygen - Performance requirements and test methods

EN 50303:2000

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust

EN 60079-1:2014

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures 'd'

EN 60079-11:2012

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Explosive atmospheres - Part 11: Equipment protection by intrinsic safety 'i'

EN 60079-20-1:2010

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data