  Description:

Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure 't'

  Purpose

IEC 60079-31:2013 is applicable to electrical equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of electrical equipment and Ex Components. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standard does not apply to electrical equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. Consideration of additional protective measures is required where the application of electrical equipment is in atmospheres, which can contain combustible dust as well as explosive gas, whether simultaneously or separately. Where the electrical equipment has to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional measures can be necessary. The measures used should not adversely affect the integrity of the enclosure. This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. The major technical changes include:  - The marked maximum surface temperature shall be measured on the external surfaces of the enclosure and the surfaces of the internal components for equipment with types of protection 'ta';  - Additional protection for arcing and sparking parts for 'ta';  - Test for internal enclosure for level 'ta' added. Keywords: explosive dust atmospheres

  Publication

Wednesday 20th of April 2016

  Reference

This standard supersedes the "EN 60079-31:2009"

Anyway is still possible use the "EN 60079-31:2009" until January 1st, 2017

  Related Standards

EN 13616-1:2025

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Overfill prevention devices for static tanks for liquid fuels - Part 1: Overfill prevention devices with closure device

EN 50104:2019/A1:2023

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Electrical equipment for the detection and measurement of oxygen - Performance requirements and test methods

EN 14973:2015

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Conveyor belts for use in underground installations - Electrical and flammability safety requirements

EN 14986:2017

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Design of fans working in potentially explosive atmospheres

EN 14994:2007

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Gas explosion venting protective systems

EN 15089:2009

Equipment for explosive atmospheres (ATEX) Directive (2014/34/EU)

Explosion isolation systems

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0