Need help?

EN 81-72:2020 Standard

wave
Save  

  Keywords:

#lift #firefighters #document #fire #well

  Directive

Lifts Directive (2014/33/EU)

  Last Official Journal reference

Monday 21st of August 2023

  Description:

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts

  Purpose

1.1 This document specifies the additional or deviating requirements to EN 81-20:2020 for new passenger and goods passenger lifts, which can be used for firefighting and evacuation purposes under firefighters control. 1.2 This document applies, when the following conditions are fulfilled: — the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; — the building design limits the flow of water into the lift well; — the firefighters lift is not used as an escape route; — the lift well and the lift environment are fire protected for at least to the same level as the building structure; — the power supply is secure and reliable; — the electrical cable(s) providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; — a suitable maintenance and verification plan is implemented. 1.3 This document does not cover: — the use of lifts with partially enclosed wells for use as firefighters lifts; — lifts installed in new or existing buildings, which are not included in fire resisting building structure; — important modification to existing lifts. 1.4 This document does not define: — the number of firefighters lifts and the floors to be served during firefighting operations; — size of safe area(s); — the use of other than the highest deck of a multi deck lift for firefighting operations. 1.5 This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.6 The following significant hazards are not dealt with in this document and are assumed to be addressed by the building designer: — not having enough or correctly located firefighters lifts to move the firefighters up the building; — a fire in the firefighters lift well, safe area, machinery space or car; — the absence of building floor identification signs at any floor; — water management is not operating correctly.

  Publication

Tuesday 27th of July 2021

  Related Standards

EN 81-73:2020

Lifts Directive (2014/33/EU)

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Pa...

EN 81-50:2020

Lifts Directive (2014/33/EU)

Safety rules for the construction and installation of lifts - Examinations and tests - Part 50: Design rules, calculations, examin...

EN 81-77:2022

Lifts Directive (2014/33/EU)

Safety rules for the construction and installations of lifts - Particular applications for passenger and goods passenger lifts - P...

EN 81-70:2021+A1:2022

Lifts Directive (2014/33/EU)

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lift - Par...

EN 81-58:2022

Lifts Directive (2014/33/EU)

Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test

EN 81-28:2022

Lifts Directive (2014/33/EU)

Safety rules for the construction and installation of lifts - Lifts for the transport of persons and goods - Part 28: Remote alarm...

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0