Need help?

EN 60670-24:2013 Standard

wave
Save  

  Keywords:

#exceeding #current #intended #entrance #main

  Directive

Low voltage (LVD) Directive (2014/35/EU)

  Last Official Journal reference

Wednesday 13th of December 2023

  Description:

Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment

  Purpose

This part of IEC 60670 applies to enclosures and parts of them for housing protective devices and other power dissipating electrical equipment intended to be used with a rated voltage not exceeding 400 V and a total incoming load current not exceeding 125 A for household and similar fixed electrical installations. These enclosures are intended to be installed where unskilled persons have access. They are intended to be integrated with electrical equipment on site by skilled persons (installers). They are intended to be installed where the prospective short circuit current does not exceed 10 kA unless they are protected by current limiting protective devices with a cut-off current not exceeding 17 kA. Enclosures complying with this standard are suitable for use, after installation, at ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C over 24 h, max. 40 °C and min. -5 °C. An enclosure which is an integral part of an electrical accessory and provides protection against external influences (e.g. mechanical impacts, ingress of solid objects or of water), is covered by the relevant standard for such an accessory. This standard does not apply to a low-voltage switchgear and controlgear assembly (ASSEMBLY) as defined in the IEC 60439 or IEC 61439 series of standards nor to a main entrance panel which may or may not be part of the distribution board. NOTE 1 A main entrance panel is a set composed by a panel or an enclosure equipped with a meter and/or the main incoming device. Main entrance panels comply with their appropriate standards or the requirements of the local supplier if any.

  Publication

Wednesday 20th of April 2016

  Related Standards

EN 62109-2:2011

Low voltage (LVD) Directive (2014/35/EU)

Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters

EN 60695-11-2:2014

Low voltage (LVD) Directive (2014/35/EU)

Fire hazard testing - Part 11-2: Test flames - 1 kW nominal pre-mixed flame: Apparatus, confirmatory test arrangement and guidance

EN 60811-510:2012

Low voltage (LVD) Directive (2014/35/EU)

Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to pol...

EN 60811-408:2012

Low voltage (LVD) Directive (2014/35/EU)

Electric and optical fibre cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability ...

EN 60730-2-8:2002

Low voltage (LVD) Directive (2014/35/EU)

Automatic electrical controls for household and similar use - Part 2-8: Particular requirements for electrically operated water va...

EN 60702-2:2002

Low voltage (LVD) Directive (2014/35/EU)

Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN 60670-24:2013 STANDARD