Need help?

EN 61010-031:2002 Standard

wave
Save  

  Keywords:

#edition #14 #modified #added #iec

This standard is superseded by:
  •   EN 61010-031:2015
  • This standard can be totally or partially supervised by:
  •   EN 61010-031:2002/A1:2008
  •   This standard is no longer addressed in the last official Journal publication of the "2023-12-13 ". This standard is addressed for the last time in the official journal publication of the "2017-09-08"

      Directive

    Low voltage (LVD) Directive (2014/35/EU)

      Last Official Journal reference

    Friday 8th of September 2017

      Description:

    Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test

      Purpose

    IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC GUIDE 104. IEC 61010-031 is a stand-alone standard. This second edition cancels and replaces the first edition published in 2002 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes: a) Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c. b) Servicing is now included within the scope. c) Extended environmental conditions are included within the scope. d) New terms have been defined. e) Tests for REASONABLY FORESEEABLE MISUSE have been added, in particular for fuses. f) Additional instruction requirements for probe assembly operation have been specified. g) Limit values for ACCESSIBLE parts and for measurement of voltage and touch current have been modified. h) SPACINGS requirements for mating of CONNECTORS have been modified. i) PROBE TIPS and SPRING-LOADED CLIPS requirements have been modified. The PROTECTIVE FINGERGUARD replace the BARRIER with new requirements. j) Insulation requirements (6.5) and test procedures (6.6.5) have been rewritten and aligned when relevant with Part 1. Specific requirements have been added for solid insulation and thin-film insulation. k) The terminology for MEASUREMENT CATEGORY I has been replaced with the designation "not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV". l) The flexing/pull test (6.7.4.3) has been partially rewritten. m) Surface temperature limits (Clause 10) have been modified to conform to the limits of IEC Guide 117. n) Requirements for resistance of PROBE WIRES to mechanical stresses have been added in Clause 12 and a new Annex D. o) Requirements have been added regarding the prevention of HAZARD from arc flash and short-circuits for SPRING-LOADED CLIPS. p) A new informative Annex E defines the dimension of the 4 mm banana CONNECTORS.

      Publication

    Wednesday 20th of April 2016

      Cessation

    This standard has been withdrawn on 2018-07-03

      Reference

    This standard supersedes the "EN 61010-2-031:1994"

    Anyway is still possible use the "EN 61010-2-031:1994" until February 1st, 2005

      Related Standards

    EN 61557-16:2015

    Low voltage (LVD) Directive (2014/35/EU)

    Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or mo...

    EN IEC 61010-2-032:2021

    Low voltage (LVD) Directive (2014/35/EU)

    Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements fo...

    EN IEC 61010-2-091:2021

    Low voltage (LVD) Directive (2014/35/EU)

    Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-091: Particular requirements for...

    EN 60335-2-54:2008/A2:2021

    Low voltage (LVD) Directive (2014/35/EU)

    Household and similar electrical appliances - Safety - Part 2-54: Particular requirements for surface-cleaning appliances for hous...

    EN 60335-2-54:2008/A12:2021

    Low voltage (LVD) Directive (2014/35/EU)

    Household and similar electrical appliances - Safety - Part 2-54: Particular requirements for surface-cleaning appliances for hous...

    EN IEC 62031:2020/A11:2021

    Low voltage (LVD) Directive (2014/35/EU)

    LED modules for general lighting - Safety specifications

      Stay up to date

    CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

    CELAB performs voluntary inspection activities on technical construction files to check their contents.

    CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

    CLICK HERE TO GET TESTS AND INFO ON THE EN 61010-031:2002 STANDARD

      ACCESS

    Search for a standard
    GO

    Register

    Already a member?
    Login

      OTHER APPLICATIONS

    If you are interested in DO160 tests, you can give a try to our other free of charge software:
    CE-Marking assistant, Version: 1.3.0