Low-voltage switchgear and controlgear - Part 2: Circuit-breakers IEC 60947-2:2016

  Purpose

This part of IEC 60947 series applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. Circuit-breakers rated above 1 000 V a.c. but not exceeding 1 500 V a.c. may also be testedto this standard. It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be. The requirements for circuit-breakers which are also intended to provide earth leakage protection are contained in Annex B. The additional requirements for circuit-breakers with electronic over-current protection are contained in Annex F. The additional requirements for circuit-breakers for IT systems are contained in Annex H. The requirements and test methods for electromagnetic compatibility of circuit-breakers are contained in Annex J. The requirements for circuit-breakers not fulfilling the requirements for over-current protection are contained in Annex L. The requirements for modular residual current devices (without integral current breaking device) are contained in Annex M. The requirements and test methods for electromagnetic compatibility of circuit-breaker auxiliaries are contained in Annex N. The requirements and test methods for d.c. circuit-breakers for use in photovoltaic (PV) applications are contained in Annex P. The requirements and test methods for circuit-breakers incorporating residual current protection with automatic reclosing functions are contained in Annex R. Supplementary requirements for circuit-breakers used as direct-on-line starters are given in IEC 60947-4-1, applicable to low-voltage contactors and starters. The requirements for circuit-breakers for the protection of wiring installations in buildings and similar applications, and designed for use by uninstructed persons, are contained in IEC 60898. The requirements for circuit-breakers for equipment (for example electrical appliances) are contained in IEC 60934. For certain specific applications (for example traction, rolling mills, marine service) particular or additional requirements may be necessary. NOTE Circuit-breakers which are dealt with in this standard can be provided with devices for automatic opening under predetermined conditions other than those of over-current and undervoltage as, for example, reversal of power or current. This standard does not deal with the verification of operation under such pre-determined conditions. The object of this standard is to state: a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply with reference to: 1) operation and behaviour in normal service; 2) operation and behaviour in case of overload and operation and behaviour in case of short-circuit, including co-ordination in service (selectivity and back-up protection); 3) dielectric properties; c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests; d) information to be marked on or given with the apparatus.

  Publication

Thursday 30th of January 2020

  Reference

This standard superseed the "EN 60947-2:2006/A1:2009 IEC 60947-2:2006/A1:2009, EN 60947-2:2006/A2:2013 IEC 60947-2:2006/A2:2013"

  Related Standards

EN 61028:1993

Low voltage (LVD) Directive (2014/35/EU)

Electrical measuring instruments - X-Y recordersIEC 61028:1991

EN 60999-2:2003

Low voltage (LVD) Directive (2014/35/EU)

Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2:...

EN 60974-5:2013

Low voltage (LVD) Directive (2014/35/EU)

Arc welding equipment - Part 5: Wire feedersIEC 60974-5:2013

EN 60974-6:2016

Low voltage (LVD) Directive (2014/35/EU)

Arc welding equipment - Part 6: Limited duty equipmentIEC 60974-6:2015

EN 60974-7:2013

Low voltage (LVD) Directive (2014/35/EU)

Arc welding equipment - Part 7:TorchesIEC 60974-7:2013

EN 60974-8:2009

Low voltage (LVD) Directive (2014/35/EU)

Arc welding equipment - Part 8: Gas consoles for welding and plasma cutting systemsIEC 60974-8:2009

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN 60947-2:2017 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0