Need help?

EN IEC 61010-2-010:2020 Standard

wave
Save  

  Keywords:

#iec #scope #intended #apply #will

  Directive

Low voltage (LVD) Directive (2014/35/EU)

  Last Official Journal reference

Wednesday 13th of December 2023

  Description:

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-010: Particular requirements for laboratory equipment for the heating of materials

  Purpose

This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 61010-2-101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. 1.1.2 Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed.

  Publication

Tuesday 22nd of June 2021

  Related Standards

EN 61869-3:2011

Low voltage (LVD) Directive (2014/35/EU)

Instrument transformers - Part 3: Additional requirements for inductive voltage transformers

EN 62479:2010

Low voltage (LVD) Directive (2014/35/EU)

Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposur...

EN 62253:2011

Low voltage (LVD) Directive (2014/35/EU)

Photovoltaic pumping systems - Design qualification and performance measurements

EN 62282-3-100:2012

Low voltage (LVD) Directive (2014/35/EU)

Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety

EN 62282-3-300:2012

Low voltage (LVD) Directive (2014/35/EU)

Fuel cell technologies - Part 3-300: Stationary fuel cell power systems - Installation

EN 62282-5-1:2012

Low voltage (LVD) Directive (2014/35/EU)

Fuel cell technologies - Part 5-1: Portable fuel cell power systems - Safety

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN IEC 61010-2-010:2020 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0