Need help?

EN IEC 61010-2-081:2020 Standard

wave
Save  

  Keywords:

#scope #new #note #document #iec

  Directive

Low voltage (LVD) Directive (2014/35/EU)

  Last Official Journal reference

Wednesday 13th of December 2023

  Description:

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes

  Purpose

This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text, except the first paragraph, by the following new text: This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this document. Examples of equipment within the scope of this document include: - analytical equipment; - automatic sampler (pipettor, aliquoter); - equipment for sample replication and amplification. NOTE 1 In the case of analytical equipment, the complete process usually includes the following steps: - taking a specific quantity of the sample; - preparing the sample by chemical, thermal, mechanical or other means; - measurement; - display, transmission or printing of the results of measurement. NOTE 2 If all or part of the equipment falls within the scope of one or more other Part 2 documents of IEC 61010 as well as within the scope of this document, consideration is given to those other Part 2 documents. 1.1.2 Equipment excluded from scope Addition: Add the following new item: aa) IEC 61010-2-101 (in vitro diagnostic (IVD) equipment). 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following new items: aa) biohazards; bb) hazardous chemical substances. 1.2.2 Aspects excluded from scope Addition: Add the following new item and note: aa) handling or manipulation of material outside the equipment. NOTE Requirements covering these subjects are the responsibility of committees preparing the relevant standards.

  Publication

Tuesday 22nd of June 2021

  Related Standards

EN 61869-4:2014

Low voltage (LVD) Directive (2014/35/EU)

Instrument transformers - Part 4: Additional requirements for combined transformers

EN 62776:2015

Low voltage (LVD) Directive (2014/35/EU)

Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications

EN 62282-5-1:2012

Low voltage (LVD) Directive (2014/35/EU)

Fuel cell technologies - Part 5-1: Portable fuel cell power systems - Safety

EN 62368-1:2014

Low voltage (LVD) Directive (2014/35/EU)

Audio/video, information and communication technology equipment - Part 1: Safety requirements (IEC 62368-1:2014, modified)

EN 62368-1:2014/AC:2015

Low voltage (LVD) Directive (2014/35/EU)

Audio/video, information and communication technology equipment - Part 1: Safety requirements (IEC 62368-1:2014, modified)

EN 62395-1:2013

Low voltage (LVD) Directive (2014/35/EU)

Electrical resistance trace heating systems for industrial and commercial applications - Part 1: General and testing requirements

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN IEC 61010-2-081:2020 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0