Need help?

EN IEC 61010-2-012:2022/A11:2022 Standard

wave
Save  

  Keywords:

#treated #additional #function #hazards #used

  Directive

Low voltage (LVD) Directive (2014/35/EU)

  Last Official Journal reference

Wednesday 13th of December 2023

  Description:

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-012: Particular requirements for climatic and environmental testing and other temperature conditioning equipment

  Purpose

1 Scope and objectThis clause of Part 1 is applicable except as follows:1.1.1 Equipment included in scopeReplacement:Replace the first paragraph by the following:This group safety publication is primarily intended to be used as a product safety standard forthe products mentioned in the scope, but shall also be used by technical committees in thepreparation of their publications for products similar to those mentioned in the scope of thisstandard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.This Part 2 of IEC 61010 specifies safety requirements for electrical equipment and theiraccessories within the categories a) through c), wherever they are intended to be used,whenever that equipment incorporates one or more of the following characteristics:– A REFRIGERATING SYSTEM that is acted on or impacted by an integral heating function suchthat the combined heating and cooling system generates additional and/or more severeHAZARDS than those for the two systems if treated separately.– The materials being treated in the intended application introduce significant heat into theREFRIGERATING SYSTEM that the cooling system in the application yield additional and/ormore severe HAZARDS than those for the cooling system if operated at the maximum RATEDambient alone.– An irradiation function for the materials being treated presenting additional HAZARDS.– A function to expose the materials being treated to excessive humidity, carbon dioxide,salt mist, or other substances which may result in additional HAZARDS.– A function of MECHANICAL MOVEMENT presenting additional HAZARDS.– Provision for an OPERATOR to walk-in to the operating area to load or unload the materialsbeing treated.

  Publication

Wednesday 11th of January 2023

  Amendment

This standard is an amendment for "EN IEC 61010-2-012:2022"

  Related Standards

EN IEC 61010-2-130:2021

Low voltage (LVD) Directive (2014/35/EU)

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-130: Particular requirements fo...

EN 61204:1995

Low voltage (LVD) Directive (2014/35/EU)

Low-voltage power supply devices, d.c. output - Performance characteristics

EN 61386-23:2004/A11:2010

Low voltage (LVD) Directive (2014/35/EU)

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

EN 61386-23:2004

Low voltage (LVD) Directive (2014/35/EU)

Conduit systems for cable management - Part 23: Particular requirements - Flexible conduit systems

EN 61386-22:2004/A11:2010

Low voltage (LVD) Directive (2014/35/EU)

Conduit systems for cable management - Part 22: Particular requirements - Pliable conduit systems

EN 61386-22:2004/AC:2004

Low voltage (LVD) Directive (2014/35/EU)

Conduit systems for cable management - Part 22: Particular requirements - Pliable conduit systems

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN IEC 61010-2-012:2022/A11:2022 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0