Need help?

EN ISO 14160:2021 Standard

wave
Save  

  Keywords:

#note #document #see #device #inactivation

  Directive

Medical devices Regulation ((EU) 2017/745)

  Last Official Journal reference

Wednesday 5th of July 2023

  Description:

Sterilization of health care products - Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives - Requirements for characterization, development, validation and routine control of a sterilization process for medical devices (ISO 14160:2020)

  Purpose

This document specifies requirements for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin.This document covers the control of risks arising from contamination with bacteria and fungi by application of a liquid chemical sterilization process. Risks associated with other microorganisms can be assessed using other methods (see NOTE 1).This document is not applicable to material of human origin.This document does not describe methods for the validation of the inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (see NOTE 2 and NOTE 3).This document does not describe methods for validation of the inactivation or elimination of protozoa and parasites.The requirements for validation and routine control described in this document are only applicable to the defined sterilization process of a medical device, which is performed after the manufacturing process, and do not take account of the lethal effects of other bioburden reduction steps (see NOTE 4).This document does not specify tests to establish the effects of any chosen sterilization process upon the fitness for use of the medical device (see NOTE 5).This document does not cover the level of residual sterilizing agent within medical devices (see NOTE 6).Guidance for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin is provided in informative Annex A.NOTE 1 The prior application of risk management principles to medical devices utilizing animal tissues, as described in ISO 22442-1 is important. ISO 18362 provides information on control of microbial risks during processing of cell-based health-care products.NOTE 2 Liquid chemical sterilizing agents traditionally employed to sterilize animal tissues in medical devices might not be effective in inactivating the causative agents of TSE such as bovine spongiform encephalopathy (BSE), or scrapie. Satisfactory validation in accordance with this document does not necessarily demonstrate inactivation of infective agents of this type. Risk controls related to sourcing, collection and handling of animal materials are described in ISO 22442-2.NOTE 3 The validation of the inactivation, elimination, or elimination and inactivation of viruses and TSE agents is described in ISO 22442-3.NOTE 4 Manufacturing processes for medical devices containing animal tissues frequently include exposure to chemical agents which can significantly reduce the bioburden on the medical device. Following the manufacturing process, a medical device is exposed to a specified sterilization process.NOTE 5 Such testing is a crucial part of the design and development of a medical device.NOTE 6 ISO 10993-17 specifies a method to establish allowable limits for residues of sterilizing agents.NOTE 7 Standards for quality management systems (see ISO 13485) can be used in the control of all stages of manufacture including the sterilization process.

  Publication

Wednesday 5th of January 2022

  Related Standards

EN ISO 11737-2:2020

Medical devices Regulation ((EU) 2017/745)

Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validati...

EN ISO 11135:2014/A1:2019

Medical devices Regulation ((EU) 2017/745)

Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a ste...

EN ISO 10993-10:2023

Medical devices Regulation ((EU) 2017/745)

Biological evaluation of medical devices - Part 10: Tests for skin sensitization (ISO 10993-10:2021)

EN ISO 25424:2019/A1:2022

Medical devices Regulation ((EU) 2017/745)

Sterilization of health care products - Low temperature steam and formaldehyde - Requirements for development, validation and rout...

EN ISO 25424:2019

Medical devices Regulation ((EU) 2017/745)

Sterilization of health care products - Low temperature steam and formaldehyde - Requirements for development, validation and rout...

EN ISO 17664-1:2021

Medical devices Regulation ((EU) 2017/745)

Processing of health care products - Information to be provided by the medical device manufacturer for the processing of medical d...

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software: