Need help?

EN ISO 11810-1:2009 Standard

wave
Save  

  Keywords:

#part #purpose #induced #cover #laser

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Lasers and laser-related equipment - Test method and classification for the laser resistance of surgical drapes and/or patient protective covers - Part 1: Primary ignition and penetration (ISO 11810-1:2005)

  Purpose

This part of ISO 11810 is applicable to disposable and reusable, as well as woven and non-woven materials used as surgical drapes and other patient protective covers which claim to be laser-resistant. The purpose of this part of ISO 11810 is to provide a standardized method for testing and classifying surgical drapes and other patient protective covers with respect to laser-induced hazards. An appropriate classification system is given. It is not the purpose of this part of ISO 11810 to serve as a general fire safety specification, and as such, this part of ISO 11810 does not cover other sources of ignition. It also does not cover the issue of laser-induced secondary ignition. All materials reflect portions of the beam and it is necessary for the user to decide whether specular reflectance may be a hazard. This measurement, however, is not covered in this part of ISO 11810.

  Publication

Friday 17th of November 2017

  Related Standards

EN 80601-2-58:2009

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-58: Particular requirements for the basic safety and essential performance of lens removal d...

EN ISO 9170-1:2008

Medical devices Directive (93/42/EEC)

Terminal units for medical gas pipeline systems - Part 1: Terminal units for use with compressed medical gases and vacuum (ISO 917...

EN ISO 10651-6:2009

Medical devices Directive (93/42/EEC)

Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 6: Home-care ventilat...

EN ISO 10651-4:2009

Medical devices Directive (93/42/EEC)

Lung ventilators - Part 4: Particular requirements for operator-powered resuscitators (ISO 10651-4:2002)

EN ISO 10651-2:2009

Medical devices Directive (93/42/EEC)

Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 2: Home care ventilat...

EN ISO 10555-1:2009

Medical devices Directive (93/42/EEC)

Sterile, single-use intravascular catheters - Part 1: General requirements (ISO 10555-1:1995, including Amd 1:1999 and Amd 2:2004)

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN ISO 11810-1:2009 STANDARD