EN ISO 11810-2:2009 Standard

wave
Save  

  Keywords:

#part #materials #testing #laser #purpose

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Lasers and laser-related equipment - Test method and classification for the laser-resistance of surgical drapes and/or patient-protective covers - Part 2: Secondary ignition (ISO 11810-2:2007)

  Purpose

This part of ISO 11810 is applicable to disposable and re-usable, as well as woven and non-woven materials used as surgical drapes and/or patient protective covers which claim to be laser-resistant. The purpose of this part of ISO 11810 is to provide a standardized method for testing and classifying surgical drapes and/or patient protective covers with respect to laser-induced hazards. An appropriate classification system is given. It is not the purpose of this part of ISO 11810 to serve as a general fire safety specification. This part of ISO 11810 is limited to testing the secondary ignition of materials that are rated Ι1 or Ι2 from ISO 11810-1. All materials reflect portions of the beam and it is necessary for the user to decide whether specular reflection may be a hazard. This measurement, however, is not covered in this part of ISO 11810. The results of this part of ISO 11810 are not to be applied to other wavelengths and temporal formats. The 20 W CO2 laser (continuous wave) has been selected as the laser to be used for this part of ISO 11810.

  Publication

Friday 17th of November 2017

  Reference

This standard supersedes the "EN ISO 11810-2:2007"

Anyway is still possible use the "EN ISO 11810-2:2007" until March 21st, 2010

  Related Standards

EN ISO 3826-2:2008

Medical devices Directive (93/42/EEC)

Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction...

EN ISO 7396-1:2007/A1:2010

Medical devices Directive (93/42/EEC)

Medical gas pipeline systems - Part 1: Pipeline systems for compressed medical gases and vacuum (ISO 7396-1:2007)

EN ISO 8835-2:2009

Medical devices Directive (93/42/EEC)

Inhalational anaesthesia systems - Part 2: Anaesthetic breathing systems (ISO 8835-2:2007)

EN ISO 8185:2009

Medical devices Directive (93/42/EEC)

Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems (ISO 8185:2007)

EN ISO 7886-4:2009

Medical devices Directive (93/42/EEC)

Sterile hypodermic syringes for single use - Part 4: Syringes with re-use prevention feature (ISO 7886-4:2006)

EN ISO 7886-3:2009

Medical devices Directive (93/42/EEC)

Sterile hypodermic syringes for single use - Part 3: Auto-disable syringes for fixed-dose immunization (ISO 7886-3:2005)

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN ISO 11810-2:2009 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0