Aseptic processing of health care products - Part 5: Sterilization in place (ISO 13408-5:2006)

  Purpose

1.1 This part of ISO 13408 specifies the general requirements for sterilization in place (SIP) applied to product contact surfaces of the equipment used in the manufacture of sterile health care products by aseptic processing and offers guidance on qualification, validation, operation and control. NOTE SIP can be achieved by using steam or other gaseous or liquid sterilizing agents. Specific guidance on steam sterilization in place, which is the most common method used, is given in Annex A. 1.2 This part of ISO 13408 applies to processes where sterilizing agents are delivered to the internal surfaces of equipment that can come in contact with the product. 1.3 This part of ISO 13408 does not apply to processes where equipment is dismantled and delivered to a sterilizer. 1.4 This part of ISO 13408 does not supersede or replace national regulatory requirements, such as Good Manufacturing Practices (GMPs) and/or compendial requirements that pertain in particular national or regional jurisdictions. 1.5 This part of ISO 13408 does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies, such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.

  Publication

Friday 17th of November 2017

  Reference

This standard supersedes the "EN 13824:2004"

Anyway is still possible use the "EN 13824:2004" until December 31st, 2011

  Related Standards

EN 1865-1:2010+A1:2015

Medical devices Directive (93/42/EEC)

Patient handling equipment used in road ambulances - Part 1: General stretcher systems and patient handling equipment

EN 60601-2-10:2000/A1:2001

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-10: Particular requirements for the safety of nerve and muscle stimulatorsIEC 60601-2-10:198...

EN 60601-2-16:1998

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-16: Particular requirements for the safety of haemodialysis, haemodiafiltration and haemofil...

EN 60601-2-13:2006/A1:2007

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-13: Particular requirements for the safety and essential performance of anaesthetic systemsI...

EN 60601-2-13:2006

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-13: Particular requirements for the safety and essential performance of anaesthetic systemsI...

EN 60601-2-12:2006

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-12: Particular requirements for the safety of lung ventilators - Critical care ventilatorsIE...

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN ISO 13408-5:2011 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0