Need help?

EN ISO 22442-3:2007 Standard

wave
Save  

  Keywords:

#medical #management #part #cover #tissue

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (ISO 22442-3:2007)

  Purpose

This part of ISO 22442 specifies requirements for the validation of the elimination and/or inactivation of viruses and TSE agents during the manufacture of medical devices (excluding in vitro diagnostic medical devices) utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It applies where required by the risk management process as described in ISO 22442-1. It does not cover other transmissible and non-transmissible agents. NOTE 1 Analysis and management of risk is described in ISO 22442-1. Conventional processes used for sterilization, when used for the treatment of animal tissues for medical devices, have not been shown to be completely effective in inactivating the causative agents of transmissible spongiform encephalopathy. Selective sourcing is extremely important (see ISO 22442-1 and ISO 22442-2). NOTE 2 ISO 11135, ISO 11137, ISO 11737-1, ISO 13408, ISO 14160, ISO 14937 and ISO 17665 may be relevant for bacteria, moulds and yeast (see Bibliography). This part of ISO 22442 does not cover the utilization of human tissues in medical devices. This part of ISO 22442 does not specify a quality management system for the control of all stages of production of medical devices.

  Publication

Friday 17th of November 2017

  Reference

This standard supersedes the "EN 12442-3:2000"

Anyway is still possible use the "EN 12442-3:2000" until June 30th, 2008

  Related Standards

EN 62220-1-2:2007

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum...

EN 13544-2:2002+A1:2009

Medical devices Directive (93/42/EEC)

Respiratory therapy equipment - Part 2: Tubing and connectors

EN ISO 11608-7:2017

Medical devices Directive (93/42/EEC)

Needle-based injection systems for medical use - Requirements and test methods - Part 7: Accessibility for persons with visual imp...

EN 12006-2:1998+A1:2009

Medical devices Directive (93/42/EEC)

Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 2: Vascular prostheses including c...

EN 12006-3:1998+A1:2009

Medical devices Directive (93/42/EEC)

Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 3: Endovascular devices

EN 12470-1:2000+A1:2009

Medical devices Directive (93/42/EEC)

Clinical thermometers - Part 1: Metallic liquid- in-glass thermometers with maximum device

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN ISO 22442-3:2007 STANDARD