Need help?

EN ISO 23328-2:2009 Standard

wave
Save  

  Keywords:

#protect #intended #bsf #breathing #filter

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Breathing system filters for anaesthetic and respiratory use - Part 2: Non-filtration aspects (ISO 23328-2:2002)

  Purpose

This part of ISO 23328 specifies requirements for non-filtration aspects of breathing system filters (BSF) intended for anaesthetic and respiratory use, and addresses connection ports, leakage, resistance to flow, packaging, marking and information supplied. The test method is intended for BSF used with a clinical breathing system. It is not applicable to other types of filter, e.g. those designed to protect vacuum sources or gas sample lines, to filter compressed gases, or to protect test equipment for physiological respiratory measurements.

  Publication

Friday 17th of November 2017

  Reference

This standard supersedes the "EN ISO 23328-2:2008"

Anyway is still possible use the "EN ISO 23328-2:2008" until March 21st, 2010

  Related Standards

EN 60627:2001

Medical devices Directive (93/42/EEC)

Diagnostic X-ray imaging equipment - Characteristics of general purpose and mammographic anti-scatter gridsIEC 60627:2001

EN ISO 80601-2-55:2018

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory ga...

EN ISO 8185:2009

Medical devices Directive (93/42/EEC)

Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems (ISO 8185:2007)

EN ISO 7886-4:2009

Medical devices Directive (93/42/EEC)

Sterile hypodermic syringes for single use - Part 4: Syringes with re-use prevention feature (ISO 7886-4:2006)

EN ISO 21649:2009

Medical devices Directive (93/42/EEC)

Needle-free injectors for medical use - Requirements and test methods (ISO 21649:2006)

EN ISO 5840:2009

Medical devices Directive (93/42/EEC)

Cardiovascular implants - Cardiac valve prostheses (ISO 5840:2005)

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN ISO 23328-2:2009 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0