Need help?

EN 60522:1999 Standard

wave
Save  

  Keywords:

#assemblies #assembly #sufficient #determine #accuracy

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Determination of the permanent filtration of X-ray tube assembliesIEC 60522:1999

  Purpose

This standard defines the concept of permanent filtration in X-ray tube assemblies for medical diagnosis and radiotherapy and describes a method for its determination. It contains requirements for statements of compliance for accompanying documents and for marking on X-ray tube assemblies. Methods are given to determine the permanent filtration in an X-ray tube assembly with an accuracy that is sufficient to enable the appropriate additional filtration to be provided in order to attain the desired total filtration.

  Publication

Friday 17th of November 2017

  Related Standards

EN ISO 11990:2018

Medical devices Directive (93/42/EEC)

Lasers and laser-related equipment - Determination of laser resistance of tracheal tube shaft and tracheal cuffs (ISO 11990:2018)

EN ISO 22442-1:2020

Medical devices Directive (93/42/EEC)

Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO 22442-1:2020)

EN ISO 22523:2006

Medical devices Directive (93/42/EEC)

External limb prostheses and external orthoses - Requirements and test methods (ISO 22523:2006)

EN ISO 22675:2016

Medical devices Directive (93/42/EEC)

Prosthetics - Testing of ankle-foot devices and foot units - Requirements and test methods (ISO 22675:2016)

EN ISO 81060-1:2012

Medical devices Directive (93/42/EEC)

Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type (ISO 81060-1:2007)

EN ISO 11990-1:2014

Medical devices Directive (93/42/EEC)

Lasers and laser-related equipment - Determination of laser resistance of tracheal tubes - Part 1: Tracheal tube shaft (ISO 11990-...

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN 60522:1999 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0