EN 60601-2-1:1998/A1:2002 Standard

wave
Save  

  Keywords:

#radiotherapy #performance #edition #operation #medical

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Medical electrical equipment - Part 2-1: Particular requirements for the safety of electron accelerators in the range of 1 MeV to 50 MeVIEC 60601-2-1:1998

  Purpose

Other names: IEC 60601-2-1:1998/A1:2002 IEC 60601-2-1:2009 applies to the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes requirements to be complied with by manufacturers in the design and construction of electron accelerators for use in radiotherapy; it does not attempt to define their optimum performance requirements. Its purpose is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such medical electrical equipment. It places limits on the degradation of medical electrical equipment performance beyond which it can be presumed that a fault condition exists and where an interlock then operates to prevent continued operation of the me equipment. This third edition cancels and replaces the second edition published in 1998 and its Amendment 1 (2002). It constitutes a technical revision. This third edition addresses the following issues not covered in previous editions: - alignment with the new relevant collateral standards; - new technologies in radiotherapy, including stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT), intensity modulated radiotherapy (IMRT), electronic imaging devices (e.g. EPID) and moving beam radiotherapy (dynamic therapy).

  Publication

Friday 17th of November 2017

  Amendment

This standard is an amendment for "EN 60601-2-1:1998"

  Reference

This standard supersedes the "EN 60601-2-1:1998"

Anyway is still possible use the "EN 60601-2-1:1998" until June 1st, 2005

  Related Standards

EN 60601-2-25:1995/A1:1999

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-25: Particular requirements for the safety of electrocardiographsIEC 60601-2-25:1993

EN 14563:2008

Medical devices Directive (93/42/EEC)

Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of mycobactericidal or tuberculocidal activi...

EN 1865-2:2010+A1:2015

Medical devices Directive (93/42/EEC)

Patient handling equipment used in road ambulances - Part 2: Power assisted stretcher

EN ISO 15223-1:2016

Medical devices Directive (93/42/EEC)

Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requir...

EN ISO 15004-1:2009

Medical devices Directive (93/42/EEC)

Ophthalmic instruments - Fundamental requirements and test methods - Part 1: General requirements applicable to all ophthalmic ins...

EN ISO 15002:2008

Medical devices Directive (93/42/EEC)

Flow-metering devices for connection to terminal units of medical gas pipeline systems (ISO 15002:2008)

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN 60601-2-1:1998/A1:2002 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0