EN ISO 10993-13:2010 Standard

wave
Save  

  Keywords:

#part #used #biological #polymers #test

  Directive

Active implantable medical devices Directive (90/385/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010)

  Purpose

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only non-resorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity. NOTE An informative text discussing environmental stress cracking (ESC) of polymers is included as a potential aid to the design of degradation studies (see Annex B). The biological activity of the debris and soluble degradation products is not addressed in this part of ISO 10993, but should be evaluated according to the principles of ISO 10993-1, ISO 10993-16 and ISO 10993-17. Because of the wide range of polymeric materials used in medical devices, no specific analytical techniques are identified or given preference. No specific requirements for acceptable levels of degradation products are provided in this part of ISO 10993.

  Publication

Friday 17th of November 2017

  Reference

This standard supersedes the "EN ISO 10993-13:2009"

Anyway is still possible use the "EN ISO 10993-13:2009" until December 31st, 2010

  Related Standards

EN ISO 11138-3:2009

Active implantable medical devices Directive (90/385/EEC)

Sterilization of health care products - Biological indicators - Part 3: Biological indicators for moist heat sterilization process...

EN ISO 10993-12:2012

Active implantable medical devices Directive (90/385/EEC)

Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012)

EN ISO 11737-1:2006/AC:2009

Active implantable medical devices Directive (90/385/EEC)

Sterilization of medical devices - Microbiological methods - Part 1: Determination of a population of microorganisms on products (...

EN ISO 11737-1:2006

Active implantable medical devices Directive (90/385/EEC)

Sterilization of medical devices - Microbiological methods - Part 1: Determination of a population of microorganisms on products (...

EN ISO 11607-1:2009

Active implantable medical devices Directive (90/385/EEC)

Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging sy...

EN ISO 11140-1:2009

Active implantable medical devices Directive (90/385/EEC)

Sterilization of health care products - Chemical indicators - Part 1: General requirements (ISO 11140-1:2005)

  Stay up to date

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0