Need help?

EN 55015:2006 Standard

wave
Save  

  Keywords:

#standard #function #intended #provisions #primary

This standard is superseded by:
  •   EN 55015:2013
  • This standard can be totally or partially supervised by:
  •   EN 55015:2006/A1:2007
  •   EN 55015:2006/A2:2009
  •   This standard is no longer addressed in the last official Journal publication of the "2022-06-10 ". This standard is addressed for the last time in the official journal publication of the "2016-05-13"

      Directive

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

      Last Official Journal reference

    Friday 13th of May 2016

      Description:

    Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

      Purpose

    This standard applies to the emission (radiated and conducted) of radiofrequency disturbances from: - all lighting equipment with a primary function of generating and/or distributing light intended for illumination purposes, and intended either for connection to the low voltage electricity supply or for battery operation; - the lighting part of multi-function equipment where one of the primary functions of this is illumination; - independent auxiliaries exclusively for use with lighting equipment; - UV and IR radiation equipment; - neon advertising signs; - street/flood lighting intended for outdoor use; - transport lighting (installed in buses and trains). The frequency range covered is 9 kHz to 400 GHz. Multi-function equipment which is subjected simultaneously to different clauses of this standard and/or other standards shall meet the provisions of each clause/standard with the relevant functions in operation. The limits in this standard have been determined on a probabilistic basis to keep the suppression of disturbances within economically reasonable limits while still achieving an adequate level of radio protection and electromagnetic compatibility. In exceptional cases, additional provisions may be required.

      Publication

    Wednesday 20th of April 2016

      Cessation

    This standard has been withdrawn on 2016-06-12

      Related Standards

    EN 60947-5-1:2004

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circ...

    EN 60204-31:2013

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    Safety of machinery - Electrical equipment of machines - Part 31: Particular safety and EMC requirements for sewing machines, unit...

    EN 50529-2:2010

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    EMC Network Standard - Part 2: Wire-line telecommunications networks using coaxial cables

    EN 50550:2011/AC:2012

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    Power frequency overvoltage protective device for household and similar applications (POP)

    EN 55012:2007

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the pr...

    EN 55014-2:1997

    Electromagnetic compatibility (EMC) Directive (2014/30/EU)

    Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - P...

      Stay up to date

    CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

    CELAB performs voluntary inspection activities on technical construction files to check their contents.

    CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

    CLICK HERE TO GET TESTS AND INFO ON THE EN 55015:2006 STANDARD

      ACCESS

    Search for a standard
    GO

    Register

    Already a member?
    Login

      OTHER APPLICATIONS

    If you are interested in DO160 tests, you can give a try to our other free of charge software:
    CE-Marking assistant, Version: 1.3.0