EN 60601-2-5:2000 Standard

wave
Save  

  Keywords:

#edition #iec #related #change #added

  Directive

Medical devices Directive (93/42/EEC)

  Last Official Journal reference

Wednesday 14th of April 2021

  Description:

Medical electrical equipment - Part 2-5: Particular requirements for the safety of ultrasonic physiotherapy equipmentIEC 60601-2-5:2000

  Purpose

IEC 60601-2-5:2009 applies to the basic safety and essential performance of ultrasonic physiotherapy equipment employing a single plane unfocused circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard can also be applied to ultrasonic physiotherapy equipment used for compensation or alleviation of disease, injury or disability. This third edition cancels and replaces the second edition published in 2000. This edition constitutes a technical revision. The numbering was revised to agree with IEC 60601-1:2005 (third edition). Beyond this, essential performance characteristics are defined in 201.4.3.101, guidance on maintenance is added in 201.7.9.2.1, a new requirement regarding dielectric withstand was added in 201.8.8.3. The clause on transducer surface temperature rise, 201.11, has been modified to allow for simulated use conditions. Measurements of ultrasound-related parameters are now referenced to IEC 61689:2007 (second edition). The most important change in the ultrasound-related parameters is the definition of effective radiating area, 201.3.207. This change will also affect the value of the effective intensity and its uncertainty.

  Publication

Friday 17th of November 2017

  Related Standards

EN 60601-2-12:2006

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-12: Particular requirements for the safety of lung ventilators - Critical care ventilatorsIE...

EN 60522:1999

Medical devices Directive (93/42/EEC)

Determination of the permanent filtration of X-ray tube assembliesIEC 60522:1999

EN ISO 14408:2009

Medical devices Directive (93/42/EEC)

Tracheal tubes designed for laser surgery - Requirements for marking and accompanying information (ISO 14408:2005)

EN 80601-2-59:2009

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening ther...

EN 80601-2-58:2009

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-58: Particular requirements for the basic safety and essential performance of lens removal d...

EN 80601-2-35:2009

Medical devices Directive (93/42/EEC)

Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating device...

  Stay up to date

CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

CELAB performs voluntary inspection activities on technical construction files to check their contents.

CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

CLICK HERE TO GET TESTS AND INFO ON THE EN 60601-2-5:2000 STANDARD

  ACCESS

Search for a standard
GO

Register

Already a member?
Login

  OTHER APPLICATIONS

If you are interested in DO160 tests, you can give a try to our other free of charge software:
CE-Marking assistant, Version: 1.3.0