EN 61676:2002 Standard

wave
Save  

  Keywords:

#safety #calibration #requirements #standard #concerned

This standard is superseded by:
  •   EN 61676:2002/A1:2009
  • This standard can be totally or partially supervised by:
  •   EN 61676:2002/A1:2009
  •   Directive

    Medical devices Directive (93/42/EEC)

      Last Official Journal reference

    Wednesday 14th of April 2021

      Description:

    Medical electrical equipment - Dosimetric instruments used for non-invasive measurement of X-ray tube voltage in diagnostic radiologyIEC 61676:2002

      Purpose

    Specifies the performance requirements of instruments as used in the non-invasive measurement of X-ray tube voltage up to 150 kV and the relevant compliance tests. Describes the method for calibration and gives guidance for estimating the uncertainty in measurements performed under conditions different from those during calibration. This standard is not concerned with the safety aspect of such instruments. The requirements for electrical safety applying to them are contained in IEC 61010-1.

      Publication

    Friday 17th of November 2017

      Related Standards

    EN 14563:2008

    Medical devices Directive (93/42/EEC)

    Chemical disinfectants and antiseptics - Quantitative carrier test for the evaluation of mycobactericidal or tuberculocidal activi...

    EN 1985:1998

    Medical devices Directive (93/42/EEC)

    Walking aids - General requirements and test methods

    EN 556-1:2001/AC:2006

    Medical devices Directive (93/42/EEC)

    Sterilization of medical devices - Requirements for medical devices to be designated "STERILE" - Part 1: Requirements for terminal...

    EN 556-2:2015

    Medical devices Directive (93/42/EEC)

    Sterilization of medical devices - Requirements for medical devices to be designated ''STERILE" - Part 2: Requirements for aseptic...

    EN 1041:2008

    Medical devices Directive (93/42/EEC)

    Information supplied by the manufacturer of medical devices

    EN 1060-4:2004

    Medical devices Directive (93/42/EEC)

    Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated non-invasive sphygm...

      Stay up to date

    CELAB is Notified Body No.2037 for the EMC Directive and Italian office of a Notified Body for the RED Directive.

    CELAB performs voluntary inspection activities on technical construction files to check their contents.

    CELAB can accomplish all the required tests in order to affix the CE-marking related to EMC, LVD, RED, MDD, machines and many others.

    CLICK HERE TO GET TESTS AND INFO ON THE EN 61676:2002 STANDARD

      ACCESS

    Search for a standard
    GO

    Register

    Already a member?
    Login

      OTHER APPLICATIONS

    If you are interested in DO160 tests, you can give a try to our other free of charge software:
    CE-Marking assistant, Version: 1.3.0